System alarms & logs, 0 system alarms, Chapter 6. system alarms & logs – CANOGA PERKINS 9145E NID Software Version 3.1 User Manual

Page 98: System alarms, Chapter 6 system alarms & logs

Advertising
background image

System Alarms & Logs

9145E NID Software User’s Manual

83

Chapter 6

System Alarms & Logs

6.0 System Alarms

Use the System Alarms screen to view alarms and faults on the 9145E.

To view alarm status, select System Alarms (4) from the Main Menu and press Enter. The
System Alarms screen (Figure 6-1) opens. Press Esc to return to the Main Menu.

Figure 6-1 System Alarm screen

Temperature Status reflects the internal temperature of the 9145E.

Canoga Perkins Corp. Ethernet Network Interface Device 15-JUN-2009
9145E-101-1-0 V03.10(GA0014) 14:44:49
-------------------------------------SYSTEM ALARMS-----------------------------

Link Remote Fault SFP Transmitter
User Port Up N/A N/A
Network Port Up No OK
MP Port Disabled N/A N/A
MGMT UTP Port Disabled

Link Loss Fwd User->Net No
Link Loss Fwd Net->User No

48V DC Power Supply A Status OK 5.25 Volts Output (4.83 < OK < 5.49)
48V DC Power Supply B Status OK 5.28 Volts Output (4.83 < OK < 5.49)
Main Board Voltages All mainboard voltages OK
Fan Status Both Fans Ok
Temperature Status OK 26.0C (0.0C < OK < 70.0C)

Hit 'ESC' to return to previous menu
------------------------------------Messages-----------------------------------

Advertising