Adjustment channel Description
Adjustment range / selection
Factory setting
Relay
Relay selection
system dependent
system dependent
Type
Circulation Type
Demand, Thermal, Timer,
Therm.+Timer, Demand+Timer
Thermal
Sensor
Circulation sensor selection system dependent
system dependent
Ton
Switch-on temperature
10 ... 59 °C [50 ... 138 °F]
40 °C [104 °F]
Toff
Switch-off temperature
11 ... 60 °C [52 ... 140 °F]
45 °C [114 °F]
Timer
Timer
-
-
Days of the week
Day selection
All days, Monday ... Sunday, Continue -
Timer
Time frame adjustment
00:00 ... 23:45
-
Sensor
FS08 sensor input selection system dependent
system dependent
Delay
Demand delay time
0 ... 2 s
1 s
Runtime
Runtime
01:00 ... 15:00 min
03:00 min
Break time
Break time
10 ... 60 min
30 min
Funct.
Activation / Deactivation
Activ., Deactivated
Deactivated
Arrangement / Opt. functions / Add new function... / Circulation
The time frames can be adjusted in steps of 15 minu-
tes. The cursor can be moved along the time line by
pressing buttons
or
4
.
The beginning of a time frame can be determined by
pressing button
1
. The end of a time frame can be
determined by pressing button
3
.