STIEBEL ELTRON SOM 10 User Manual

Page 55

Advertising
background image

en

55

Adjustment channel Description

Adjustment range / selection

Factory setting

Relay

Relay selection

system dependent

system dependent

Type

Circulation Type

Demand, Thermal, Timer,
Therm.+Timer, Demand+Timer

Thermal

Sensor

Circulation sensor selection system dependent

system dependent

Ton

Switch-on temperature

10 ... 59 °C [50 ... 138 °F]

40 °C [104 °F]

Toff

Switch-off temperature

11 ... 60 °C [52 ... 140 °F]

45 °C [114 °F]

Timer

Timer

-

-

Days of the week

Day selection

All days, Monday ... Sunday, Continue -

Timer

Time frame adjustment

00:00 ... 23:45

-

Sensor

FS08 sensor input selection system dependent

system dependent

Delay

Demand delay time

0 ... 2 s

1 s

Runtime

Runtime

01:00 ... 15:00 min

03:00 min

Break time

Break time

10 ... 60 min

30 min

Funct.

Activation / Deactivation

Activ., Deactivated

Deactivated

Arrangement / Opt. functions / Add new function... / Circulation

The time frames can be adjusted in steps of 15 minu-
tes. The cursor can be moved along the time line by
pressing buttons

or

4

.

The beginning of a time frame can be determined by
pressing button

1

. The end of a time frame can be

determined by pressing button

3

.

Advertising