STIEBEL ELTRON SOM 10 User Manual

Page 58

Advertising
background image

en

58

Arrangement / Opt. functions / Add new function... / Function block

Adjustment channel Description

Adjustment range / selection Factory setting

Relay

Relay

R2

R2 ... R14

Thermostat a

Thermostat a

Yes, No

No

Th-a on

Switch-on temperature Thermostat a -40 ... 250 °C [-40 ... 482 °F]

40 °C [104 °F]

Th-a off

Switch-off temperature Thermostat a -40 ... 250 °C [-40 ... 482 °F]

45 °C [114 °F]

Sensor

Sensor thermostat a

S1 ... S12

S4

Thermostat b

Thermostat b

Yes, No

No

Th-b on

Switch-on temperature Thermostat b -40 ... 250 °C [-40 ... 482 °F]

40 °C [104 °F]

Th-b off

Switch-off temperature Thermostat b -40 ... 250 °C [-40 ... 482 °F]

45 °C [114 °F]

Sensor

Sensor thermostat b

S1 ... S12

S5

∆T function

Differential function

Yes, No

No

∆Ton

Switch-on temperature difference

1.0 ... 50.0 K [2.0 ... 100.0 °Ra] 5.0 K [10.0 °Ra]

∆Toff

Switch-off temperature difference

0.5 ... 49.5 K [1.0 ... 99.0 °Ra] 3.0 K [6.0 °Ra]

Sen. So.

Heat source sensor

Controller S1 ... S12

S6

Sen. Sink

Heat sink sensor

Controller S1 ... S12

S7

Timer

Timer

-

-

Days of the week

Day selection

All days, Monday ... Sunday,
Continue

-

Timer

Time frame adjustment

00:00 ... 23:45

-

Funct.

Activation/Deactivation

Activ./Deactivated

Deactivated

Advertising