17 troubleshooting – STIEBEL ELTRON SOM 10 User Manual

Page 76

Advertising
background image

76

en

Directional pad flashes red.

Sensor fault. The error code !Sensor fault is

displayed instead of a temperature on the sensor
display channel.

Short circuit or line break

Disconnected temperature sensors can be

checked with an ohmmeter. Please check the resis-

tance values corresponding with the table.

17 Troubleshooting

If a malfunction occurs, a message will appear on the display of the controller.

fuse

The controller is protected by a fuse. The fuse holder (which also holds the spare
fuse) becomes accessible when the cover is removed. To replace the fuse, pull the
fuse holder from the bottom.

WARNING!

Electric shock!
Upon opening the housing, live parts are exposed.

Î

Always disconnect the controller from power supply
before opening the housing!

The display is permanently off.

Press button

5

. Display illuminated?

no

yes

Check the supply line and recon-
nect it.

The fuse of the controller could
be blown. The fuse holder (which
holds the spare fuse) becomes
accessible when the cover is remo-
ved.The fuse can then be replaced.

Check the power supply of the controller. Is it
disconnected?

no

yes

Controller has been in
standby, everything o.k.

°C °F

Ω

Pt500

Ω

Pt1000

Ω

KTY

°C °F Ω

Pt500

Ω

Pt1000

Ω

KTY

-10 14

481

961

1499

55

131

607

1213

2502

-5

23

490

980

1565

60

140

616

1232

2592

0

32

500

1000

1633

65

149

626

1252

2684

5

41

510

1019

1702

70

158

636

1271

2778

10

50

520

1039

1774

75

167

645

1290

2874

15

59

529

1058

1847

80

176

655

1309

2971

20

68

539

1078

1922

85

185

664

1328

3071

25

77

549

1097

2000

90

194

634

1347

3172

30

86

559

1117

2079

95

203

683

1366

3275

35

95

568

1136

2159

100 212

693

1385

3380

40 104

578

1155

2242

105 221

702

1404

3484

45 113

588

1175

2327

110 230

712

1423

3590

50 122

597

1194

2413

115 239

721

1442

3695