en

Display illuminated?

If not, press button

5

. Display illumina-

ted now?

Is the pump current enabled by
the controller?

Does the pump start up in
manual operation?

The solar circuit pump does not work, although the collector is considerably
warmer than the store.

yes

no

yes

There is no current; check

fuses / replace them and check
power supply.

The adjusted temperature dif-

ference for starting the pump is
too high; choose a value which
makes more sense.

no

yes

Is the pump stuck?

Turn the pump shaft using a

screwdriver; now passable?

no

yes

Stores cool down at night.

Collector circuit pump runs

during the night?

no

yes

Check controller

Check the non-return valves in

the flow and the return pipe for
functional efficiency.

Sufficient store insulation?

yes

no

Increase insulation.

Insulation close enough to the

store?

yes

no

Replace insulation or increase it.

Are the store connections

insulated?

yes

no

Insulate the connections.

Warm water outflow upwards?

no

yes

Change connection and let the

water flow sidewards or through
a siphon (downwards); less store

losses now?

no

yes

o.k.

a

Collector temperature at night
is higher than the outdoor
temperature.

no

yes

no

Controller might be defective

- replace it.