10 heating – STIEBEL ELTRON SOM 10 User Manual
Page 59
en
59
Irradiation switch
The Irrad. switch function can be used for operating
a relay depending on the measured irradiation value.
The allocated relay is switched on if the adjusted irra-
diation value remains exceeded for the adjusted dura-
tion. If the irradiation falls below the adjusted value for
the adjusted duration, the relay is switched off.
If the Inverted option is activated, the relay operates
vice versa.
Adjustment channel Description
Adjustment range / selection
Factory setting
Relay
Relay selection
system dependent
system dependent
Irrad.
Switch-on irradiation
50 ... 1000 W / m²
200 W / m²
Duration
Switch-on duration
0 ... 30 min
2 min
Inverted
Inverted switching option
Yes, No
No
Funct.
Activation / Deactivation
Activ., Deactivated
Deactivated
Arrangement / Opt. functions / Add new function... / Irradiation switch
10 Heating
In this menu, all adjustments for the heating part of
the arrangement or for the heating circuits respec-
tively can be made.
Demands can be activated, heating circuits can be pa-
rameterized and optional functions can be selected
and adjusted.