8

2.4

SD card slot

The controller is equipped with
an SD card slot.
With an SD card, the following
functions can be carried out:
• Store measurement and

balance values onto the SD
card. After the transfer to
a computer, the values can
be opened and visualized, e. g. in a spreadsheet
programme.

• Prepare adjustments and parameterizations on a

computer and transfer them via the SD card.

• Store adjustments and parameterizations on the

SD card and, if necessary, retrieve them from there.

• Download firmware updates from the Internet and

install them on the controller.

A standard SD card is not included with the SOM 10.
For more information about using an SD card, see
page 69.

3

Step-by-step parameterization

The SOM 10 is a controller that offers a broad variety
of functions to the user. At the same time, the user has
a lot of freedom in configurating them. Therefore, to
set up a complex system, careful planning is required.
We recommend drawing a sketch of the system first.
If planning, hydronic execution and electrical connec-
tion have all been carried out successfully, proceed as
follows:

1. Running the commissioning menu
The commissioning menu is run after the first connec-
tion and after every reset. It will request the following
basic adjustments:
• Menu language
• Temperature unit
• Volume unit
• Pressure unit
• Energy unit
• Time
• Date
• Solar system
• Hydronic variant
At the end of the commissioning menu, a safety en-
quiry follows. If the safety enquiry is confirmed, the
adjustments are saved.
For further information about the commissioning
menu see page 12.

2. Registering sensors
If flowmeters, flow switches, Grundfos Direct Sen-
sors™ and/or external extension modules are con-
nected, these have to be registered in the In-/Outputs
menu.
For further information about the registration of mo-
dules and sensors see page 72.

3. Activating solar optional functions
The basic solar system has been adjusted during com-
missioning. Now, optional functions can be selected,
activated and adjusted.
Free relays can be allocated to optional functions
which require a relay. The controller always suggests
the numerically smallest free relay.
Sensors can be allocated to more than one function.
For further information about the solar optional func-
tions see page 34.

4. Activating optional arrangement functions
Now, optional functions for the non-solar part of the
arrangement can be selected, activated and adjusted.
Free relays can be allocated to optional functions
which require a relay. The controller always suggests
the numerically smallest free relay.
Sensors can be allocated any number of times without
impairing any other functions.
For further information about the optional arrange-
ment functions see page 47.

5. Adjusting heating circuits and activating op-

tional heating functions

Now, heating circuits can be activated and adjusted.
Internal heating circuits are only offered as long as at
least 3 relays are free.
For the heating part of the arrangement, optional
functions can be selected, activated and adjusted.
To heating circuits and optional functions which re-
quire one or more relays, the corresponding number
of free relays can be allocated. The controller always
suggests the numerically smallest free relay.
Sensors can be allocated any number of times without
impairing any other functions.
For further information about heating circuits and op-
tional heating functions see page 59.