Current limitation

error

The number of connected

sensor amplifiers exceeds

the allowable range.

Use sensor amplifiers within

the allowable range.

57

Communication

error between

sensor amplifiers

An error occurred during

communication between

sensor amplifiers.

Check if there is a noise

source around the DL-EP1.

If the sensor communication

indicator is flashing red, turn

the power on again.

70

IP address

duplicate error

The IP address is the same

as another device.

Check the IP address

setting.

100

System error

The IP address is incorrect.

Contact your nearest

KEYENCE office.

101

System error

A default gateway setting

error occurred.

102

System error

An attempt to read data in

EEPROM such as the MAC

address has failed.

103

System error

An attempt to start the

protocol stack has failed.

104

System error

An attempt to access

FlashROM has failed.

150

System error

The number of held IDs is

incorrect.

151

System error

The number of sensors is

incorrect.

152

System error

An initial read error occurred.

Error

ID

Number

Code

Description

Cause

Actions

Advertising