4 message communication 3-48 – KEYENCE DL-EP1 User Manual

Page 78

Advertising
background image

- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (IB) -

3-4 Message Communication

3-48

3

C

om
m

uni

ca

tin

g

w

ith

IB

S

er

ie

s

Group4

0394H

(916)

Ext. IN3

function

selection

*14

Sets the function to be assigned to external input 3.

Parameter range: 0 to 4 (initial value: 0)

0: Timing input

1: Bank A input

2: Bank B input

3: Laser emission stop input

4: Not use

R/W

DINT

0395H

(917)

Ext. IN4

function

selection

*14

Sets the function to be assigned to external input 4.

Parameter range: 0 to 4 (initial value: 4)

0: Adjust input

1: Bank A input

2: Bank B input

3: Laser emission stop input

4: Not use

R/W

DINT

0396H

(918)

Bank

switching

method

Sets the bank switching method.

Parameter range: 0 to 1 (initial value: 0)

0: Button

1: External Input

R/W

DINT

0397H

(919)

(Reserved for system)

0398H

(920)

Save zero-

shift state

Sets whether to store the zero shift status.

Parameter range: 0 to 1 (initial value: 0)

0:OFF

1:ON

R/W

DINT

0399H

(921)

(Reserved for system)

039AH

(922)

Display digit

Sets the display resolution.

When measurement mode is % mode:

0: Initial setting (dEFLt) (initial value)

1: (Reserved for system)

2: (Reserved for system)

3:0.01

4:0.1

5:1

When measurement mode is dimension mode:

0: Initial setting (dEFLt) (initial value)

1: (Reserved for system)

2:0.001

3:0.01

4:0.1

5:1

R/W

DINT

039BH

(923)

Power save

function

Sets the power saving function.

Parameter range: 0 to 2 (initial value: 0)

0:OFF

1: Half

2: All

R/W

DINT

039CH

(924)

(Reserved for system)