Entering an external input to a sensor amplifier

Available external inputs: External input 1, External input 2, External input 3, External

input 4

Device assignments:

"External Input (5 Words (10 Bytes)) assembly instance

(Instance ID): 65H" (Page 3-16)

This example shows how to enter external input 2 to the sensor amplifier ID01.
(1)The device value in the OUT area to which an external input request was

assigned is linked via cyclic communication and the external input of the sensor

amplifier is turned on or off.

(2)You can check the input status of the sensor amplifier with the external input

response.

• If the external input or sensor amplifier input signal line from cyclic

communication is ON, the sensor amplifier recognizes that the external
input is ON and executes input operation (OR operation). For example, if
the external input or sensor amplifier input signal line from cyclic
communication is ON when laser transmission stop input is assigned to
external input n, laser transmission stop input is executed.

• To use bank switching, set "bank switching method" to "external input

switching".

PLC

(1)

External Input request
OUT area [2]Bit0

(2)

External Input response

IN area [30]Bit0

Sensor amplifier

External Input

External input 2 to ID 01

1
0

ON

OFF

1
0