Assignment to out area (scanner to dl-ep1), Assignment to out area (scanner to dl-ep1) -16, 3 cyclic communication 3-16 – KEYENCE DL-EP1 User Manual

Page 46

Advertising
background image

- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (IB) -

3-3 Cyclic communication

3-16

3

C

om
m

uni

ca

tin

g

w

ith

IB

S

er

ie

s

The data to the sensor amplifier is assigned to the OUT area of the EtherNet/IP
scanner.

„

External Input (5 Words (10 Bytes)) assembly instance (Instance ID): 65H

ID numbers (ID01 to ID04) are assigned for each sensor amplifier according to the
number of sensor amplifiers. The ID numbers larger than the number of connected

sensor amplifiers and ID05 to ID15 are not assigned.

* External inputs 1 to 4 are assigned any function and used. For details on the

functions to be assigned, refer to "IB User's Manual".

Assignment to OUT Area (Scanner to DL-EP1)

DL-EP1 data

Scanner's OUT area

Address 0
Address 1

Address 9

External Input
(Assembly Instance: 101)

1-byte (8-bit) data

Name

Address

(Byte)

bit7

bit6

bit5

bit4

bit3

bit2

bit1

bit0

External

Input

Request 1

(External

Input 1)

0

ID08

. . . . .

ID01

1

Reserved for

system

ID15

. . . . .

ID09

External

Input

Request 2

(External

Input 2)

2

ID08

. . . . .

ID01

3

Reserved for

system

ID15

. . . . .

ID09

External

Input

Request 3

(External

Input 3)

4

ID08

. . . . .

ID01

5

Reserved for

system

ID15

. . . . .

ID09

External

Input

Request 4

(External

Input 4)

6

ID08

. . . . .

ID01

7

Reserved for

system

ID15

. . . . .

ID09

External

Input

Request 5

(Unassigned)

8

ID08

. . . . .

ID01

9

Reserved for

system

ID15

. . . . .

ID09

Advertising