4 message communication 3-38 – KEYENCE DL-EP1 User Manual
Page 68

- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (IB) -
3-4 Message Communication
3-38
3
C
om
m
uni
ca
tin
g
w
ith
IB
S
er
ie
s
Attributes for IB Series
Designate the ID number (01H to 04H) of a sensor amplifier as the instance ID.
If the parameter range is data with a decimal point, read or write the data as an
integer, ignoring the decimal point. For example, if you want to write +1.235
(dimension mode) in HIGH setting value (BANK0), write +1235.
Class
Attribute
ID
Name
Description
Attribute
Data
Type
Group1
0320H
(800)
Group1
Entry count
Indicates the group 1 entry count.
Parameter range: 29
R
DINT
0321H
(801)
Error status
*1
Reads the error status.
If an error occurs, the corresponding bit is set to
ON.
Bit 0: Overcurrent error (ErC)
Bit 1: EEPROM error (ErE)
Bit 2: Head error (transmitter/receiver) ErH/t r
Bit 3: T/R reverse connection error
(alternate flashing of ErH/rt and ErH/tr)
Bit 4: Transmitter internal error (ErH/t.int
Bit 5: Receiver error (ErH/r
Bit 6: Transmitter error (ErH/t
Bit 7: Transmitter laser error ErH/LASEr
Bit 8: Model mismatch error rH/rAnGE
Bit 9: Ref. light quantity registration error
(rG/dArK, ErG/inF)
Bit 10: Adjust error
(Er. AdJ/dArK, Er. AdJ/ovEr, Er. AdJ/inF)
Bit 11: Communication error between sensor
amplifiers Er.coM
R
DWORD
0322H
(802)
Warning
Status
(Check
Output State)
Reads the warning status.
If a warning occurs, the corresponding bit is set
to ON.
Bit 0: 1 when the sensor amplifier is in the check
output state (check output is ON when
N.O. and OFF when N.C.)
R
DWORD
0323H
(803)
Warning
function
operating
state (Check
Output
Function
Operation
Status)
Reads the warning function operation status.
If the warning function is in operation, the
corresponding bit is set to ON.
Bit 0: 1 when the check output function is ON
R
DWORD
0324H
(804)
Judgement
output/Check
output
Reads the sensor output status.
If the output is ON, the corresponding bit is set to
ON.
Bit 0: HIGH
Bit 1: LOW
Bit 2: GO
Bit 3: Check output
R
DWORD
0325H
(805)
Judgment
value (P.V.)
*2
Read the comparator value (P.V.).
When measurement mode is % mode: -999.99 to
+999.99
When measurement mode is dimension mode:
-99.999 to +99.999
R
DINT