4 message communication 3-36 – KEYENCE DL-EP1 User Manual

Page 66

Advertising
background image

- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (IB) -

3-4 Message Communication

3-36

3

C

om
m

uni

ca

tin

g

w

ith

IB

S

er

ie

s

00H

91H

(145)

to 92H

(146)

:

93H

(147)

Current

Value 0 (ID

Number 4)

Indicates the current value 0 of the sensor of ID

number 4.

Parameter range:

-2147483648 to 2147483647

R

WORD

94H

(148)

to 9EH

(158)

Current

Value 0 (ID

Number 5) to

(ID Number

15)

(Unassigned)

R

DINT

9FH

(159)

Reserved for system

A0H

(160)

to AEH

(174)

Current

Value 1 (ID

Number 1) to

(ID Number

15)

(Unassigned)

R

DINT

AFH

(175)

Reserved for system

B0H

(176)

Sensor

Status Mask

Setting

Set up the condition to determine if the sensor

error or warning is a recoverable DL-EP1 error

(MS LED blinks in red). If mask is selected, MS

LED does not blink in red when a sensor error or

warning occurs.

Parameter range: 0 to 1 (initial value: 0)

0: Not mask

1: Mask

R/W

UINT

B1H

(177)

Sensor

Connected

Number

Indicates the number of connected sensor

amplifiers.

Parameter range: 0 to 4

R

UINT

B2H

(178)

to C7H

(199)

Reserved for system

0300H

(768)

Error Code

(ID number

0)

Indicates the error code of ID number 0.

Parameter range: 0 to 65535

R

UINT

0301H

(769)

to

0303H

(771)

:

0304H

(772)

Error Code

(ID number

4)

Indicates the error code of ID number 4.

Parameter range: 0 to 65535

R

UINT

Instance

ID

Attribute

ID

Name

Description

Attribute

Data

Type

Advertising