KEYENCE DL-EP1 User Manual
Page 55

3-4 Message Communication
3-25
3
C
om
m
uni
ca
tin
g
w
ith
IB
S
er
ie
s
- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (IB) -
(5) Reading the number of decimal places from a sensor amplifier
Message communication reads the number of decimal places of settings read
from the sensor amplifier.
"(5) Reading the number of decimal places in the parameter from a sensor
For the IB Series, if measurement mode is "% mode" and the current value
is 12.50%, data is stored as follows:
Data: 1250
Number of decimal places: 2
Perform calculation from the read data and the number of decimal places.
IB
Command
Response
DL-EP1
Scanner
<Details of command>
Service code: 4CH
Class ID: 67H
Instance ID: 01H
Attribute ID: 0325H(805)
Reads the number of decimal places of
the IB comparator value (P.V. value).
Reference
125012.5012.5%
Number of
decimal places
2 1