4 message communication 3-39 – KEYENCE DL-EP1 User Manual

Page 69

Advertising
background image

3-4 Message Communication

3-39

3

C

om
m

uni

ca

tin

g

w

ith

IB

S

er

ie

s

- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (IB) -

Group1

0326H

(806)

Internal

measurement

value (R.V.)

*2

Read the R.V. value.

When measurement mode is % mode: -999.99 to

+999.99

When measurement mode is dimension mode:

-99.999 to +99.999

R

DINT

0327H

(807)

Peak-hold

value in hold

mode

*2

When the hold function is other than sample

hold

Reads the peak hold value during sampling.

When measurement mode is % mode: -999.99

to +999.99

When measurement mode is dimension mode:

-99.999 to +99.999

When the hold function is sample hold

When measurement mode is % mode: -999.98

When measurement mode is dimension mode:

-99.998

R

DINT

0328H

(808)

Bottom-hold

value in hold

mode

*2

When the hold function is other than sample

hold

Reads the bottom-hold value during sampling.

When measurement mode is % mode: -999.99

to +999.99

When measurement mode is dimension mode:

-99.999 to +99.999

When the hold function is sample hold

When measurement mode is % mode: -999.98

When measurement mode is dimension mode:

-99.998

R

DINT

0329H

(809)

(Reserved for system)

032AH

(810)

Analog

output value

Reads the current analog output value. (Main unit

only)

Parameter range:

Voltage: -5.000 to +5.000 (when an error occurs:

+5.500)

4 to 20 mA:+4.00 to +20.00 (when an error occurs:

+3.00)

OFF: Fixed at 0

R

DINT

032BH

(811)

Bank status

Reads the number of the currently operating

bank.

Check the number of bank where the sensor

amplifier is actually operating from this attribute.

Parameter range: 0 to 3

0: Bank 0

1: Bank 1

2: Bank 2

3: Bank 3

R

DINT

032CH

(812)

Timing status

Reads the timing status of the operating sensor

amplifier.

Check the timing status of the actually operating

amplifier from this attribute.

Parameter range: 0 to 1

0: Sampling now in progress

1: Sampling not in progress

R

DINT

032DH

(813) to

0331H

(817)

(Reserved for system)

Class

Attribute

ID

Name

Description

Attribute

Data

Type

Advertising