4 message communication 3-46 – KEYENCE DL-EP1 User Manual

Page 76

Advertising
background image

- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (IB) -

3-4 Message Communication

3-46

3

C

om
m

uni

ca

tin

g

w

ith

IB

S

er

ie

s

Group4

0385H

(901)

Averaging/

High-pass

filter

Sets the averaging/high-path filter.

Parameter range: 0 to 19 (initial value: 5)

0 : 1 times

1 : Twice

2 : 4 times

3 : 8 times

4 : 16 times

5 : 64 times

6 : 256 times

7 : 1024 times

8 : 4096 times

9 : 16384 times

10 : 0.1Hz

11 : 0.2Hz

12 : 0.5Hz

13 : 1Hz

14 : 2Hz

15 : 5Hz

16 : 10Hz

17 : 20Hz

18 : 50Hz

19 : 100Hz

R/W

DINT

0386H

(902)

Output mode

Sets output mode.

Parameter range: 0 to 1 (initial value: 0)

0: N.O.

1: N.C.

R/W

DINT

0387H

(903)

(Reserved for system)

0388H

(904)

Hold

function

setting

Sets the hold function.

Parameter range: 0 to 5 (initial value: 0)

0: Sample hold

1: Peak hold

2: Bottom hold

3: Peak-to-peak hold

4: Auto peak hold

5: Auto bottom hold

R/W

DINT

0389H

(905)

Auto hold

trigger level

Sets the auto peak hold trigger level or auto

bottom hold trigger level.

When measurement mode is % mode:

-999.99 to +999.99 (initial value: 90.00)

When measurement mode is dimension mode:

-99.999 to +99.999 (initial value: 9,000)

R/W

DINT

038AH

(906)

Timing input

setting

Sets the timing input.

Parameter range: 0 to 1 (initial value: 0)

0: Level

1: Edge

R/W

DINT

038BH

(907)

Delay timer

Sets the delay timer.

Parameter range: 0 to 3 (initial value: 0)

0: OFF

1: On delay

2: Off delay

3: One shot

R/W

DINT

Class