3-4 Message Communication
3-47
3
C
om
m
uni
ca
tin
g
w
ith
IB
S
er
ie
s
- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (IB) -
Group4
038CH
(908)
Timer
duration
Sets the timer duration.
Parameter range: 1 to 9999 (initial value: 60)
1 to 9999
R/W
DINT
038DH
(909)
Hysteresis
Sets the hysteresis.
When measurement mode is % mode:
0.00 to 999.99 (initial value: 0.00)
When measurement mode is dimension mode:
0 to 99.999 (initial value: 0)
R/W
DINT
038EH
(910)
Analog
output
scaling
*13
Sets the analog output scaling. (Main unit only)
Parameter range: 0 to 1 (initial value: 0)
0: Initial state
1: Free range
R/W
DINT
038FH
(911)
Analog
output upper
limit
*13
Sets the analog output upper limit. (Main unit
only)
When measurement mode is % mode:
-999.99 to +999.99 (initial value: 100.00)
When measurement mode is dimension mode:
-99.999 to +99.999 (initial value: 10,000)
R/W
DINT
0390H
(912)
Analog
output lower
limit
*13
Sets the analog output lower limit. (Main unit
only)
When measurement mode is % mode:
-999.99 to +999.99 (initial value: 0.00)
When measurement mode is dimension mode:
-99.999 to +99.999 (initial value: 0)
R/W
DINT
0391H
(913)
External
input setting
*14
Sets whether to change external input 1 to 4
function assignment from the initial state.
Parameter range: 0 to 1 (initial value: 0)
0: Initial setting
1: User setting
R/W
DINT
0392H
(914)
Ext. IN1
function
selection
*14
Sets the function to be assigned to external input 1.
Parameter range: 0 to 4 (initial value: 0)
0: Zero shift input
1: Bank A input
2: Bank B input
3: Laser emission stop input
4: Not use
R/W
DINT
0393H
(915)
Ext. IN2
function
selection
*14
Sets the function to be assigned to external input 2.
Parameter range: 0 to 4 (initial value: 0)
0: Reset input
1: Bank A input
2: Bank B input
3: Laser emission stop input
4: Not use
R/W
DINT
Class
Attribute
ID
Name
Description
Attribute
Data
Type