KEYENCE LK-H1W User Manual

Page 75

Advertising
background image

A-3

LK-H1W-M-NOA-E

Appendices

A

During setting

Head Settings

OUT settings

Error message

Cause

Remedy

ABLE Calibration

The settable range is from 1 to
99.

ABLE is left blank or 0 is set.

Enter a value into ABLE in the
range of 1 to 99.

Implement the setting so that the
lower limit value is equal to or
smaller than the upper limit
value.

A value that is larger than the
upper limit value is set in the
lower limit value of ABLE.

Implement the setting so that the
lower limit value is equal to or
smaller than the upper limit
value.

Number of alarm warnings

Sets the number of alarm
warnings. The settable range is
from 0 to 999.

The Number of alarm warnings
column is left blank.

Enter a value in the range of 0 to
999 in the column of Number of
alarm warnings.

Measurement mode

The measurement mode of the
head whose calculation method
is set to transparent object, is
not set to the measurement
mode of either "Transparent
object" or "Transparent object-2".
There is a possibility that correct
measurement cannot be made.
Are you sure you want to make
measurement?

The measurement mode of the
head whose calculation method
is set to transparent object, is
not set to the measurement
mode of either "Transparent
object" or "Transparent object-2".

This message appears when
inappropriate setting is made. If
you want to implement the
measurement as it is, select OK.
If you want to change the
setting, select NO.

Error message

Cause

Remedy

Scaling input value

Illegal entry. Enter a value in the
range of (–99.9999 to 99.9999).

The scaling setting input column
is left blank. Or any character
other than numerical value, or a
value exceeding the settable
range is set in the scaling
setting input column

In the scaling setting input
column, enter a number within
the displayed range.

The identical value cannot be
set for the Input values

The identical value is set in both
of the Input value-1 column and
Input value-2 column of scaling.

Enter different values in the
Input value-1 column and Input
value-2 column of scaling.

Scaling indication value

Illegal entry.
Enter a value in the range of
(–99.9999 to 99.9999).

The scaling setting indication
value column is left blank. Or any
character other than numerical
value, or a value exceeding the
settable range is set in the
scaling setting output column.

In the scaling setting indication
value column, enter a number
within the displayed range.