3-2 Device Maps

3-6

- CC-Link Compatible Network Unit DL-CL1 User’s Manual (SK-1000) -

Comm

u

nic
a

ti

ng

w

it

h th

e

SK-1

000 Se

ri

es

3

Remote output RY (master station -> DL-CL1)

Operating

mode

Device no.

(HEX)

Name

Communication

method

Description

Writing range

S

m

a

ll-me

mo

ry mo

de
1

S

m

a

ll-me

mo

ry mo

de
2

Mo

ni

to

r mo

de
1

RY[n] + 00
to 07

External output-
1 ID 01 to ID 08

*1

Receives external input-1 by
assigning each sensor amplifier
(ID 01 to ID 08) to each RY.

0: OFF
1: ON

RY[n] + 0F

System reserved

-

Unusable

-

RY[n] + 10
to 17

External output-
1 ID 01 to ID 08

*1

Receives external input-2 by
assigning each sensor amplifier
(ID 01 to ID 08) to each RY.

0: OFF
1: ON

RY[n] + 1F

System reserved

-

Unusable

-

RY[n] + 20
to 27

External input-3
ID 01 to ID 08

*1

Receives external input-3 by
assigning each sensor amplifier
(ID 01 to ID 08) to each RY.

0: OFF
1: ON

RY[n] + 2F

System reserved

-

Unusable

-

RY[n] + 30
to 37

External input-4
ID 01 to ID 08

*1

Receives external input-4 by
assigning each sensor amplifier
(ID 01 to ID 08) to each RY.

0: OFF
1: ON

RY[n] + 3F

System reserved

-

Unusable

-

RY[n] + 40
to 4E

(Not used)
ID 01 to ID 08

-

-

-

RY[n] + 4F
to 50

System reserved

-

Unusable

-

RY[n] + 51

Request for
command

*4

Used when communicating under
handshake control program.
This is input when requesting
command execution.

0->1: Request
execution

RY[n] + 52

System reserved

-

Unusable

-

RY[n] + 53

Request to lock
judgment value
update

-

Used to lock data update in
judgment value boxes (RWr[n] +
08 to 0D).
This may be used to obtain the
judgment values of multiple sensor
amplifiers at the same timing.
The judgment value is locked while
the update request is held.
The update lock state can be
checked by the judgment value
update lock state (RX[n] + 53).

0: Do not lock
update
1: Request
update lock

RY[n] + 54
to 5D

System reserved

-

Unusable

-

RY[n] + 5E

Request to
change
judgment value
page

*2

Used when reading judgment
value (P.V. value).
This is input when requesting to
change the judgment value page
(the ID number of the sensor
amplifier to read from).

0->1: Request
change

RY[n] + 5F

System reserved

-

Unusable

-