3-4 Command Parameter List

3-27

3

Comm

u

nic
a

ti

ng

w

it

h th

e

SK-1

000 Se

ri

es

- CC-Link Compatible Network Unit DL-CL1 User’s Manual (SK-1000) -

*1

Bit assignment for ID numbers

*2

Bit assignment for outputs

03

0101

Output ID 01

Output state of ID 01.
Each output is assigned to
the corresponding bit.*2
Same content as remote
input RX.

R

WORD

0

For each bit
0: Output OFF
1: Output ON

...

...

0108

Output ID 08

Output state of ID 08.
Each output is assigned to
the corresponding bit.*2
Same content as remote
input RX.

0201

Current value ID
01

Reads the current value of
ID 01.
Same content as the
current value in remote
register RWr.

INT32

0

...

...

0208

Current value ID
08

Reads the current value of
ID 08.
Same content as the
current value in remote
register RWr.

0301

Decimal point
information for
current value ID 01

Reads the decimal point
position of ID 01.

UINT

0: No decimal point
1: One decimal
2: Two decimals
3: Three decimals
4: Four decimals

...

...

0308

Decimal point
information for
current value ID 08

Reads the decimal point
position of ID 08.

05

0000

Number of
connectable
units

Reads the number of
connected sensor
amplifiers.

R

UINT

0

1 to 08

0101

Product code of
ID 01

Reads the product codes of
sensor amplifiers of
respective ID numbers.

R

UINT

0

4024: Main unit
4025: Expansion
unit

...

...

0108

Product code of
ID 08

0201

Head code ID 01

Not used with the SK-1000
series.

0

-

...

...

0208

Head code ID 08

10

**00

to**FF

Commands in this data category are the same as those in data category 00. When such a
command is used to read a parameter with decimal point information from a sensor amplifier, the
command can retrieve the decimal point position information.
The differences from data category 00 are as follows:
The data category specified in the command is changed from 00h o 10h. The others of the
command format are the same as in data category 00.
The decimal point position information is retrieved as a command response. For details of
communication responses, see "Command response list" (page 3-10).

Data

category

(HEX)

Data

number

(HEX)

Name

Description

Attribute

Data

type

Default

value

Parameter range

DL

ID15

ID14

ID02

ID01

bit 15

bit 14

bit 13

bit 1

bit 0

Unusable

(Not used)

Alarm output

GO

LO

HI

bit 15

bit 4

bit 3

bit 2

bit 1

bit 0