3-2 Device Maps

3-11

3

Comm

u

nic
a

ti

ng

w

it

h th

e

SK-1

000 Se

ri

es

- CC-Link Compatible Network Unit DL-CL1 User’s Manual (SK-1000) -

Number [n] denotes the first relay number assigned to the DL-CL1.

*1

Refer to

"Monitor mode 1" (page 3-19).

*2

Refer to

"Changing the BANK Number of Sensor Amplifiers" (page 3-21).

*3

Refer to

"Reading/Writing Settings or Status of a Sensor Amplifier" (page 3-23).

Refer to

"Issuing a Motion Command to a Sensor Amplifier" (page 3-22).

*4

Refer to

"Command Parameter List" (page 3-26).

Mo

ni

to

r mo

de
1

RWw[n] + 04

Select BANK
number

*2

Used when changing BANK
number.
Specifies a new BANK number.

0: BANK 0
1: BANK 1
2: BANK 3
3: BANK 3

RWw[n] + 05
to 07

System reserved

-

Unusable

-

RWw[n] + 08

Select
judgment value
box page
number

*1

Used when reading judgment
value (P.V. value).
Specifies the page number
corresponding to the sensor
amplifier ID number to be stored in
the
judgment value box.

0: Page 0
1: Page 1
2: Page 2
3: Page 3
4: Page 4

Operating

mode

Device no.

(HEX)

Name

Communication

method

Description

Writing range