4 command parameter list, Common command parameter list, Command parameter list -29 – KEYENCE DL-CL1 User Manual

Page 54: Common command parameter list -29, Command parameter list -26, 26) and, Command, Command parameter list

Advertising
background image

3-26

3

Comm

u

nic
a

ti

ng

w

it

h th

e

SK-1

000 Se

ri

es

- CC-Link Compatible Network Unit DL-CL1 User’s Manual (SK-1000) -

3-4

Command Parameter List

The following tables list the command parameters used to read/write the settings and
status of sensor amplifiers, or to issue motion commands, by creating a handshake
control program.
For details about how the master station communicates using command parameters,
see:

"Issuing a Motion Command to a Sensor Amplifier" (page 3-22)

"Reading/Writing Settings or Status of a Sensor Amplifier" (page 3-23)

The table below describes parameters which are common to the DL-CL1.

For the communication methods using these common command parameters, see
"Reading/Writing Settings or Status of a Sensor Amplifier" (page 3-23).
Attribute R: Read; W: Write

Common Command Parameter List

Data

category

(HEX)

Data

number

(HEX)

Name

Description

Attribute

Data

type

Default

value

Parameter range

00

**00 to

**FF

Refer to

"Command Parameter List for SK-1000 Series" (page 3-28).

01

0000

All unit key lock

Activates key lock on all
sensor amplifiers
connected.

W

UINT

0

0: Unlock
1: Key lock

03

0000

Error information

Possible errors, and their
contents, of sensor
amplifiers
Same content as remote
register (RWr[n] + 0).
If there are errors with
multiple ID numbers, the
error information for the
smallest error code is
reported.

R

UINT

0

Refer to

"Error

information list"
(page 3-9)
.

0001

Warning
information

Not used with the SK-1000
Series.

-

-

-

0002

Error ID number

Errors are read by
assigning sensor amplifiers
(ID 01 to ID 08) to bits 0 -
7.*1
If there are errors with
multiple ID numbers, all of
the associated bits are set
to 1.
The error with DL-CL1 is
assigned to bit 15.

WORD

0

For each bit
0: No error
1: Error

0003

Warning ID
number

Not used with the SK-1000
Series.

-

-

-

Advertising