(5) The judgment values of the sensor amplifiers of the specified ID numbers are entered into judgment

value boxes 1 to 3.
If the judgment value is correct, the parameter range is

from - 99.999 to 99.999 (SK-050).

If the current value is over range, under range, or invalid, the previous value is retained without
updating the current value. Use the value with the judgment value property.

(6) When the "request to change judgment value page" command is set to 0, the "judgment value page

change complete" parameter flips to 0. If a judgment value page change error occurred, it is cleared (0).

(7) Once the judgment values of the sensor amplifiers are updated, the judgment value boxes are

updated by cyclic transfer.

Monitor mode 2/full mode

When reading judgment values (P.V. values) in monitor mode 2 or full mode, read the
remote registers assigned to the ID numbers of the sensor amplifiers. For details of

remote registers, see

"Device Maps" (page 3-4).

When reading judgment values (P.V. values) in monitor mode 1, see

"Monitor

mode 1" (page 3-19).

This example illustrates how to read the judgment values from the sensor amplifiers of ID 01, 02, and 03.
(1) When the judgment value of a sensor amplifier is updated, the new judgment value is entered into

remote register RWr.
If the judgment value is correct, the parameter range is

from - 99.999 to 99.999 (SK-050).

If the current value is over range, under range, or invalid, the previous value is retained without
updating the current value. Use the value with the judgment value property.

(2) If the judgment value of a sensor amplifier is "invalid," the bit corresponding to the ID number of that

sensor amplifier flips to 1.

(3) If the judgment value of a sensor amplifier is "over," the bit corresponding to the ID number of that

sensor amplifier flips to 1.

(4) If the judgment value of a sensor amplifier is "under," the bit corresponding to the ID number of that

sensor amplifier flips to 1.

Point

PLC

Sensor amplifier

(2)

Comparator judgment "invalid"

Each bit of RWr09

(3)

Comparator value "over"

Each bit of RWr0A

(4)

Comparator value "under"

Each bit of RWr0B

Comparator value of ID 01 1234

4567

6789

RWr0C

Comparator value of ID 02

2345

5678

7890

RWr0E

Comparator value of ID 03

3456

8901

RWr010

(1)

Comparator value of ID 01 1234

4567

6789

Comparator value of ID 02

2345

5678

7890

Comparator value of ID 03 3456

8901

1

1

1

0

0

0