3-4 Command Parameter List

3-29

3

Comm

u

nic
a

ti

ng

w

it

h th

e

SK-1

000 Se

ri

es

- CC-Link Compatible Network Unit DL-CL1 User’s Manual (SK-1000) -

Setting/status command parameters

For the communication methods using setting/status parameters, see

"Reading/

Writing Settings or Status of a Sensor Amplifier" (page 3-23).
To reduce the number of writes to the EEPROM, a write command is executed two
seconds after it is received. If another command is received within 2 seconds, the DL-
CL1 waits for another 2 seconds before executing the two commands in batch.
After the writing completes successfully, the "EEPROM writing result" parameter
becomes "successfully completed (1)." For example, if commands are received
continually every second, they do not get executed because the DL-CL1 remains
"currently writing (0)." 2 seconds after the last command is received, the commands
received until then get executed in batch.
If data with a decimal point is used for a parameter range, ignore the decimal point
and read or write the data as an integer. For example, to write a HI setting value
(BANK 0) of "+1.235", write "+1235."
Attribute R: Read; W: Write; R/W: Read/Write
nn: ID number of sensor amplifier. Example: For nn41h and ID13, then 0D41h.
The data type is DINT (32-bit singed integer).

Data

category

(Hex)

Data

number

(Hex)

Name

Description

Attribute

Default

value

Parameter description

00

nn20

Group-1 entry count

R

24

nn21

Sensor amplifier error

*1

R

0: Overcurrent error
1: EEPROM error
2: Sensor head error
3: 0 fixed
4: 0 fixed
5: 0 fixed
6: 0 fixed
7: Head temperature/humidity
error
8: 0 fixed
9: 0 fixed
10: 0 fixed
11: Amplifier communication
error
12: 0 fixed
13: 0 fixed
14: 0 fixed
15: 0 fixed

nn22 to

nn23

Reserved

nn24

Judgment output/Alarm
output

*2

*16

R

0: HI judgment output 0: OFF,
1: ON
1: LO judgment output 0: OFF,
1: ON
2: GO judgment output 0: OFF,
1: ON
3: Alarm output 0: OFF, 1: ON

nn25

Judgment value (P.V. value)

*3

R

-99.999 to +99.999

nn26

Internal measurement value
(R.V. value)

R

-99.999 to +99.999

nn27

Peak-hold value during hold
period

*4

R

-99.999 to +99.999

nn28

Bottom-hold value during
hold period

*5

R

-99.999 to +99.999