- CC-Link Compatible Network Unit DL-CL1 User’s Manual (SK-1000) -

3-3

Communication Methods

This section describes how the CC-Link master station communicates with the DL-CL1.

"Reading an Output from a Sensor Amplifier" (page 3-18)

"Entering an External Input into a Sensor Amplifier" (page 3-18)

"Reading Judgment Values (P.V. Values) from Sensor Amplifiers" (page 3-19)

"Changing the BANK Number of Sensor Amplifiers" (page 3-21)

"Issuing a Motion Command to a Sensor Amplifier" (page 3-22)

"Rewriting a Setting Value of a Sensor Amplifier" (page 3-23)

"Reading/Writing Settings or Status of a Sensor Amplifier" (page 3-23)

Available outputs: HI, LO, GO, and alarm output.

This example reads the HI output from the sensor amplifier of ID01.
(1) The output from the sensor amplifier is brought into the remote input device by cyclic transfer.

Available external inputs: External inputs 1 - 4

This example illustrates how to enter a External input 2 into the sensor amplifier of ID01.
(1) The value of the remote output device which is assigned an external input request is linked by cyclic

transfer, so that the external input of the sensor amplifier is turned on or off.

(2) The input status of the sensor amplifier can be checked with the external input response (except for

small-memory mode 1).

• If either the external input via communication or the input signal line

of the sensor amplifier is ON, the amplifier unit recognizes that the
external input is ON and thus executes input operation (ORing).
Example: Suppose that the external input n is set to "reset input." The
reset input is executed if the external input via communication or the
input signal line of the sensor amplifier is ON.

• In cases of using the BANK change function, set the "BANK change

method" parameter of the amplifier unit to "external input change."

Reading an Output from a Sensor Amplifier

Output of sensor amplifier

RX00

(1)

Output

HI output of ID 01

1

ON

0

OFF

PLC

Sensor amplifier

Entering an External Input into a Sensor Amplifier

PLC

Sensor amplifier

(1)

External input request

RY10

(2)

External input response

RWr05 BIT0

External input

External input 2

1

ON

1

0

OFF

0

Point