1-2

PFC-6075R • 5403594 • REV D • 9/14

y

y

99 Software Zones

y

y

Dead-front Cabinet Design

y

y

2 X 16 character LCD display

y

y

Dedicated Alarm, Supervisory and Trouble Form C Relays

y

y

Analog / Addressable Sensing Technology

y

Drift Compensation

y

Drift Alert

y

NFPA 72 compliant calibrated smoke test built-in

P-Link Accessories

y

y

RA-6500R, RA-6500 or RA-6075R, RA-6075 Remote Annunciator – Maximum of 31 per system in any combination

y

y

UD-1000 Dual Line Fire Communicator – Maximum of 1 per system

y

y

CA-6075 Class A converter module – Maximum of 1 per system allows for Class A wiring of the SLC circuit, P-Link

communication bus and the two (2) built-in NAC circuits

y

y

PSN-1000 / PSN-1000(E) Intelligent Power Supply Expander – An accessory to the panel providing ten (10) amps of

additional power, with four (4) input points, six (6) notification circuits, and a P-Link interface

y

y

LED-16 Annunciator module - Maximum of 10 total per system (the total may be any combination of LED-16 and

DRV-50 LED modules) allows for up to 16 zones alarm, supervisory and trouble conditions to display, and 5 non-

programmable system LEDs that display system's overall condition

y

y

DRV-50 LED Driver module - Maximum of 10 total per system (the total may be any combination of LED-16 and DRV-50

LED modules) allows output to up to 50 LEDs, 4 dry contact inputs, and 5 non-programmable system LEDs that display

system's overall condition

y

y

RLY-5 Relay Board module - Maximum of 31 per system provides five (5) Form-C relay outputs

y

y

FCB-1000 Fire Communications Bridge module - An accessory that provides a remotely-located IP connection to the panel

y

y

FIB-1000 Fiber Interface Bridge - An accessory to the panel that converts the standard 4-wire P-Link bus to and from optic

cable capable of Class A operation; maximum of 30 total per system

y

y

SPG-1000 Serial Parallel Gateway - An accessory to the panel that provides a serial or parallel printer connection;

maximum of 31 per system

SLC Loop Accessories

• Addressable Sensors

y

Photoelectric Smoke Detector (PSA)

y

Photoelectric/Heat Smoke Detector (PSHA)

y

Fixed Temperature Heat Detector (FHA)

y

Rate of Rise/Fixed Temperature Heat Detector (RHA)

y

Addressable Isolator Base (AIB)

y

Addressable Relay Base (ARB)

y

Addressable Sounder Base (ASB)

y

Addressable Pull Station (APS)

• Addressable Modules

y

Miniature Contact Module (MCM)

y

Single Contact Module (SCM-4)

y

Dual Contact Module (DCM-4)

y

Twin Relay Module (TRM-4)

y

Monitored Output Module (MOM-4)

y

Conventional Input Zone Module (CIZM-4)

y

Short Circuit Isolator (SCI)