How the contact bridge works – Toa NX-100S Installation User Manual

Page 108

Advertising
background image

6-5

Chapter 6: APPENDIX

1.8. How the Contact Bridge Works

1.8.1. Basic operation

Whenever any variation in the contact input occurs, the input change information is communicated to the
preprogrammed output destination.

Note: No information is communicated when the contact input remains unchanged.

Network

NX-100/100S

Contact input ON

Contact output ON

NX-100/100S

Contact input

Contact output

Network communication

Input ON

Output ON

ON

Control result: OK

1.8.2. Retry operation

If a failure of contact bridge control is detected, the system automatically attempts to reestablish control after a
5-second interval (retry operation). The retry operation continues until the contact bridge has been
successfully controlled or the contact input status has changed.

Contact input

Contact output

Network communication

Input ON

5 s

Output ON

ON

Control result: NG

ON

Control result: NG

5 s

ON

Control result: OK

[Factors attributable to contact bridge
control failure]

• Contact input and output devices are not

recognized as existing in the same system.
(Their respective system names differ from
each other.)

• Contact output not set to standard mode.
• Timeout or error occurs in network

communications.

Advertising