Chapter 3: SYSTEM SETTINGS (NX-100 SETUP PROGRAM)

[Start port No.]
Enter the base number of the TCP port (other than web server, which is used by the unit). The default is
"5000." Enter the number from within the range of 1 – 65532.

The TCP ports are assigned as follows:

Port

Web server

Broadcast control

PC control

Contact bridge

Serial bridge

Port No.

Web server

Start port No. + 0

Start port No. + 1

Start port No. + 2

Start port No. + 3

Protocol

TCP

TCP

TCP

TCP

TCP

Default

80

5000

5001

5002

5003

(3) UDP port number assignment

Designate the base port number to be used by UDP.

[Start port No.]
Enter the base UDP port number to be used by the unit. The default is "5000." Enter an even number from
within the range of 1 – 65526.
The UDP ports are assigned as follows:

Port

Streaming

Error correction

Resend

Serial bridge

Fs* correction

Port No.

Start port No. + 0

Start port No. + 2

Start port No. + 4

Start port No. + 6

Start port No. + 7

Protocol

UDP

UDP

UDP

UDP

UDP

Default

5000

5002

5004

5006

5007

* Sampling frequency

Caution
Since UDP port No. 15000 is used by the unit, numbers between 14990 and 15000 cannot be used.