6-9

Chapter 6: APPENDIX

[Error indicator status]

Possible cause and remedy

Power off
AC adapter is disconnected.
→ Ensure the connection of power supply.

CPU error (CPU hang-up)
→ Contact your TOA dealer.

Data write error
Writing data failed because the unit's power is shut off or
other trouble occurs during data write or firmware update.
→ Contact your TOA dealer.

Firmware exception handling occurrence
→ Push the front-mounted Reset button to restart the unit

operation.
If this happens frequently, contact your TOA dealer.

Communications-related errors on network and control
Causes may be the following: Power-off or network
disconnection of the unit set to be controlled, duplicate
control (busy), NX-100/100S setting errors (impossible
control or communications settings), and network
equipment setting errors.
→ Establish a connection to the unit to be controlled, or

change settings of individual equipment.

Packet collision occurrence
The NX-100/100S and the connected network equipment
are in half-duplex communications, and collision occurs.
This may cause intermittent sound when audio signals are
transmitted.
→ It is preferable to use the NX-100/100S in full-duplex

communications.

Network disconnection
LAN cable is disconnected or network equipment is turned
off.
→ Ensure each connection to the network equipment.

Excessive audio signal input (Distorted output signal)

Audio signal level applied is excessively high.
→ Set the input volume control and the input level selection

switch appropriately.

(Flashes alternately.)

(Lights for
1 second
in several-
second
cycles)

or

1

2

3

4

5

6

7

LNK/ACT FD/COL

SIGNAL

PEAK

(NX-100S only)

STATUS

ERROR

RUN

No audio signal input

If this happens though the Audio input terminal is
connected to equipment, the cause may be the following
case: the external equipment is turned off, or its
connection cable is disconnected, or the NX-100S input
volume control is fully turned down.
→ Ensure the connection and power of external equipment,

and the NX-100S volume control adjustment.

NX-100S only