Toa NX-100S Installation User Manual

Page 52

Advertising
background image

3-26

Chapter 3: SYSTEM SETTINGS (NX-100 SETUP PROGRAM)

Step 5. Set the type to [Momentary] or [Latch].

Momentary: Provides output during the period between receiving an activation request and receiving

a stop request.

Latch:

Provides 1 second of output upon receiving an activation request and 1 second of output
upon receiving a stop request.

Note
[Latch] cannot be selected when setting Mode to [STATUS Output] or [ERROR Output].

1 s

1 s

Broadcast and
activation data

Contact output

Contact output

Make

Break

• Latch

Broadcast and
activation data

Contact output

Contact output

Make

Break

• Momentary

ON

ON

ON

ON

ON

ON

ON

ON

ON

ON

Activation

Stop

Activation

Stop

Caution
The unit's correct operation cannot be ensured if both activation and stop signals
are received during the 1-second output interval.

Step 6. Select Polarity from [Make] or [Break].

Make: ON when the contact is closed.
Break: ON when the contact is opened.

Step 7. Set OFF delay time from [0] – [60] seconds.

Adjust the displayed scale or enter an OFF delay time of 0 – 60 seconds for the duration between
receiving a termination request and actually turning OFF the contact. When in Resend mode (refer to

p. 3-19, Packet loss recovery

) and making broadcasts with longer delay times, set the OFF delay time

to correspond to the delay time.

Note
For more information regarding OFF delay times, refer to

p. 6-4

.