Help, Buttons, Scanning units – Toa NX-100S Installation User Manual

Page 36: P. 3-10

Advertising
background image

3-10

Chapter 3: SYSTEM SETTINGS (NX-100 SETUP PROGRAM)

5.2.3. Help

Help:

Displays help contents.

Version data: Indicates the version of the program in use.

5.3. Buttons

(1) (2)

(1) Unit scan button:

Scans all the units on the LAN.

(2) Setting upload button: Writes the IP address, subnet mask, default gateway, and name into the selected

units.

5.4. Scanning Units

Scans each unit connected to the LAN.

Step 1. Connect NX-100 and NX-100S units to the network and turn on each power.

The LNK/ACT Indicator will light.

Step 2. Either press the Unit Scan Button

or select [Scan] → [Unit scan].

The MAC address, IP address, subnet mask, default gateway, and unit name of the NX-100 and
NX-100S connected to the LAN will be displayed.
Default values are factory-preset as follows:

IP address:

192.168.1.1

Subnet mask:

255.255.255.0

Default gateway: 0.0.0.0
Name:

NX-100S or NX-100

Caution
Units can only be scanned within the effective broadcast range. (See

p. 6-3

.)

For the units that cannot be scanned, manually add only the units connected to the LAN with the System
Setting Tool.

Advertising
This manual is related to the following products: