Toa NX-100S Installation User Manual

Page 62

Advertising
background image

4-5

Chapter 4: SYSTEM SETTINGS (SETTING USING BROWSER)

(4) Port No.

Set the start port number to be used by each protocol.
The assigned port numbers are indicated.

[TCP Port No. Assignment]
• Web server

Enter the web server port number
(Range: 1 – 65535; Factory-preset: 80)

• Start port no.

Enter the first TCP port number other than the HTTP, which is used by the NX-100/100S.
(Range: 1 – 65532; Factory-preset: 5000)

[UDP Port No. Assignment]
Designate the first port number to be used by the UDP.
• Start port no.

Enter the first UDP number to be used by the unit.
(Range: EVEN numbers 1 – 65526; Factory-preset: 5000)

Caution
Since UDP port No. 15000 is used by the unit, numbers between 14990 and 15000 cannot be used.

(5) Save button

Updates the NX-100/100S setting file.

Caution
Never restart the unit or turn off the power during updates, or while the STATUS indicator on the front
panel of the NX-100/100S is flashing.

Advertising