Toa NX-100S Installation User Manual

Page 109

Advertising
background image

Contact input

Contact output

Network communication

Input OFF

Power ON

Output OFF

OFF

Control result: OK

6-6

Chapter 6: APPENDIX

1.8.3. Operation at system startup

When contact bridges are registered, the contact
input device transmits contact input status
information to the contact output device
immediately after power is switched ON. This
operation is performed for all registered contact
inputs.

Note
If a contact bridge output destination device is
not connected to the network or if the power is
OFF, the contact input device repeatedly
continues retry operation after power is switched
ON. Whenever control results in failure, the
ERROR indicator on the front panel lights for one
second.

1.8.4. Operation at power-off or power restoration

The following examples show the contact status changes from the status illustrated below when the control
input or output device's power is switched ON or OFF.

Network

Contact input device

Contact input ON

Contact output ON

Contact output device

Power ON

Power ON

[Operations caused by a change in the contact input device’s power status]

Contact input
device

Contact input ON

ON

Contact output ON

ON

Contact output
device

ON

ON

Power OFF

Power ON

Network

(Transmits initial status
information when power
is switched ON.)

(Receives contact ON
information.)

(Holds current status in
the absence of changed
information.)

[Operations caused by a change in the contact output device’s power status]

Contact input
device

Contact input ON

ON

Contact output ON

OFF

Contact output
device

ON

OFF

Power OFF

Power ON

Network

(Output turns OFF when
power is switched OFF.)

(No information is
transmitted because no
change is detected in
the contact input device.
Mismatching occurs
between contact input
and output statuses.)