Contact input setting – Toa NX-100S Installation User Manual

Page 71

Advertising
background image

4-14

Chapter 4: SYSTEM SETTINGS (SETTING USING BROWSER)

6.1. Contact Input Setting

Set the broadcast pattern to be started, and the contact bridge. When the contact input is selected, the screen
will switch over to the contact input setting screen. Select [Enable] and set the contact input contents.

(1) Operation Mode

Select from [Momentary] and [Latch]. Operations are as follows:

Momentary: The designated broadcast pattern or other unit's contact is activated while the input is ON.

The start mode stops when the input is OFF.

Latch:

When the input is turned on, the designated broadcast pattern or other unit's contact is
activated, and the start mode continues even if the input is turned OFF. The start mode stops
when the input is turned ON again.

50 ms or more

50 ms or more

Broadcast and
contact data

Contact input

Contact input

• Latch

Broadcast and
contact data

Contact input

Contact input

Make

Break

Make

Break

• Momentary

ON

ON

ON

ON

ON

ON

ON

ON

ON

ON

Activation

Stop

Activation

Stop

(2) Polarity

Set to either [Make] or [Break].
Make: ON when contact is closed.
Break: ON when contact is opened.

Advertising