Connections to terminal plugs – Toa NX-100S Installation User Manual

Page 16

Advertising
background image

2-5

Chapter 2: UNIT AND SOFTWARE INSTALLATIONS

2. CONNECTIONS TO TERMINAL PLUGS

Wire the removable terminal plugs for power input (NX-100 only), audio input and output, and control input
and output as follows:

[Cable size and width to strip]

15 mm

7 mm

7 mm

Solid cable and stranded cable

Shielded cable

Application

Size

Width to Strip

For power supply terminal

For audio terminal

For control terminal

AWG24 – 12

AWG28 – 16

NX-100 only

Caution
Avoid soldering stranded or shielded cable, as contact resistance may increase when the cable is tightened
and the solder is crushed, possibly resulting in an excessive rise in joint temperatures.

[Wiring procedure]

Step 1. Wiring the supplied removable

terminal plug.

1-1. Loosen the terminal screws to insert

the wire.

1-2. Tighten the terminal screws.

Ensure that the wire does not break
free when pulled. If the wire does pull
free, repeat the connection procedure
from the start.

Step 2. Insert the wired terminal plug into the

corresponding terminal block in the
unit's rear panel.

Step 3. Tighten the fixing screws.

Cautions
• Do not reverse Steps 1 and 2. Poor contact may result if force is applied to the unit's internal circuit board

pins while the terminal screws are being tightened.

• Use an appropriate type screwdriver for terminal plug wiring.

NX-100 only

AUDIO OUTPUT

AUDIO INPUT

H

C

E

H

C

E

MIC

LINE

VOL

UME

INPUT

Removable
terminal plug

1

2

3

NX-100 rear panel

Tighten

Tighten

This figure represents the NX-100.