Toa NX-100S Installation User Manual

Page 15

Advertising
background image

2-4

Chapter 2: UNIT AND SOFTWARE INSTALLATIONS

MIC

LINE

VOLUME

INPUT

24V

DC INPUT

AUDIO OUTPUT

FG

7

6

7

6

AUDIO INPUT

8 C

5

4

3

2

1

C

8

5

4

3

2

1

CONTACT OUTPUT

CONTACT INPUT

RS-232C

200mA

10/100M

H C E

H C E

AC ADAPTER

24V 200mA

DC INPUT

7

6

8 C

5

4

2 3

1

7

6

C

8

5

4

3

2

1

Open collector output
Withstand voltage: 30 V DC
Control current: 50 mA maximum
Pulse width: 1 s (when in Latch mode)

[Control Output Specifications]

To other unit's control input

• Control Output Terminal Connections

Connect the control input terminals of all other
connected units using 2 control lines.

Caution

Be sure to connect only these
control lines to other unit's control
input terminals.
Connecting in parallel with control
lines from other equipment may
cause the unit to malfunction.

This figure represents the NX-100.

CONTACT
OUTPUT

1 – 8

C

+24 V DC

External

power supply

Relay

Diode

GND

Note
To control a power distributor or PA
amplifier mounted in the same rack
as the unit using the unit's control
output terminals, provide an external
relay and power supply as shown
below to perform control with the
relay contacts.

No-voltage "make" contact input
Short circuit current: 10 mA
Open voltage: 12 V
Pulse width: Over 50 ms

[Control Input Specifications]

To other unit's
control output

• Connections to the Control Input Terminal

Connect the control output terminals of all other
connected units using 2 control lines.

• RS-232C Interface Connections

The NX-100 can be used to control such RS-232C
components as DTE and DCE components over a
network.
Use a "straight" cable fitted with a 9-pin D-sub
connector when connecting to DTE components
such as PCs.
Use a "cross" cable fitted with a 9-pin D-sub
connector for connecting to DCE components such
as modems.

NX-100 only

Tips
• Refer to

p. 2-5, CONNECTIONS TO TERMINAL PLUGS

, for control terminal connection procedures.

• When not using the RS-232C interface, place the supplied RS-232C cover over the terminal to protect it

against dust. NX-100 only

Advertising
This manual is related to the following products: