Chapter 4: SYSTEM SETTINGS (SETTING USING BROWSER)

7. SERIAL BRIDGE SETTING NX-100 only

Perform serial bridge settings.

(1) Enable/Disable Selection

Select "Enable" when using this function. All items can be ready for entry.

(2) Network Setting

[Protocol]
Select the serial bridge communication configuration.

TCP Server: The original unit carries out communications as a TCP server. The NX-100 unit connected to

this server must be set as a TCP client in its protocol settings.

TCP Client: The original unit carries out communications as a TCP client. The target NX-100 unit must

be set as a TCP server in its protocol settings.

UDP:

Carries out communications using UDP. The target NX-100 unit's protocol settings must be
set to UDP.

[Target Unit's IP Address]
Enter the target unit's IP address and port number.

Note
Enter the global IP address if using the Internet.