Chapter 3: SYSTEM SETTINGS (NX-100 SETUP PROGRAM)

6.6.2. Contact output setting

Step 1. Click on the [Contact] tab of the System Setting Tool.

Step 2. Click on the selection button for contact output channel numbers.

The setting contents will be displayed.

Step 3. Tick the checkbox for [Enable contact].

The setting contents can be edited.

Step 4. Select Mode from [Standard], [STATUS Output], and [ERROR Output].

Standard:

Provides output by way of control from a PC or contact inputs of other units or
original unit.

STATUS Output: Provides contact output synchronizing with the unit's STATUS indicator operation.
ERROR Output:

Provides contact output synchronizing with the unit's ERROR indicator operation.

Note: To use the Contact bridge function, select [Standard].