41 change leading code setting – ADLINK ND-6017 User Manual
Page 88
 
80
• Command Set
3.41 Change Leading Code Setting
@Description
User can use this command to change command leading code setting 
as he desired. 
@Syntax
~(Addr)10(C1)(C2)(C3)(C4)(C5)(C6)<CR>
~
Command leading code.
(Addr)
Address ID, range (00 - FF).
10
Change command leading code setting.
(C1)
Leading code 1, for read configuration status, 
firmware version, etc. default is $. 
(1-character) 
(C2)
Leading code 2, for read synchronize sampling, 
digital output ,default is #. 
(1-character) 
(C3)
Leading code 3, for change configuration. 
default is %. (1-character) 
(C4)
Leading code 4, for read alarm status, enable alarm, 
etc. default is @. (1-character) 
(C5)
Leading code 5, for read command leading code, 
change leading code, etc. default is ~. 
(1-character) 
(C6)
Leading code 6, this leading code is reserved. 
default is *. (1-character) 
@Response
!(Addr)< CR>
 or 
?(Addr)<CR> 
 
!
Command is valid.
?
Command is invalid.
(Addr)
Address ID.
(6011/D, 6012/D, 6013
6014D, 6017, 6018)