P/N: 4FU020-010 v6.2, 06-08-10

©2010 Vortech Engineering, LLC

All Rights Reserved, Intl. Corp. Secured

28

8. CHARGE AIR COOLER INSTALLATION

(CHARGE COOLED KITS ONLY)

, cont’d

10. 2005-2009 models: Locate assembly 8N104-

125. Confirm that the assembly is complete.

2010 Models: use assembly 8N104-127.

11. Attach the provided ring terminal to the ground

wire on the suplied water pump plug harness.

Connect the supplied length of 16GA wire to

the positive wire using the supplied butt con-

nector. Connect the water pump harness to

the water pump.

12. Locate the supplied water pump (8F001-403),

two 2-3/8" adel clamps, and water pump

mounting bracket. Place the adel clamps on

the water pump. Using the supplied 1/4-20

hardware, secure the water pump and clamps

to the mounting bracket. When installing,

attach the water pump ground wire to one of

the water pump mounting clamps using the

previously installed ring terminal. (See Fig.

8B-g.)

2010 Models: use water pump bracket depict-

ed in Fig. 8B-g2.

13. Attach the pump assembly to the two 8mm x

35mm long bolts previously installed and

secure using the 8mm nuts and washers pro-

vided. (See Fig. 8B-h.)

2010 Models: see Fig. 8B-h2

Fig. 8B-g

Fig. 8B-h (2005-2009 Models)

MOUNTING

BRACKET

ADEL

CLAMP

PLUG

HARNESS

WATER

PUMP

HOSE TO

PASSENGER’S

SIDE SHOCK

TOWER

B.

WATER COOLER ASSEMBLY

INSTALLATION, cont’d

8mm

HARDWARE

Fig. 8B-g2 (2010 Models)

Fig. 8B-h2 (2010 Models)