Flown arrays, T10 array, Limitation – d&b T-Series User Manual

Page 20: Preparations, Order of assembly, Suspend the flying frame, Prepare the first t10 cabinet, Attach the flying frame to the first t10 cabinet

Advertising
background image

4.1.

Flown arrays

4.1.1. T10 Array

Limitation
A maximum of 20 x T10 cabinets are allowed to be flown.

Preparations

- Prepare the flying cables and link cables according to the number of

amplifier channels and cabinets used.

- Ensure the HF sections of the T10 cabinets to be used are set to Line

source.

Order of assembly

1. Suspend the Flying frame

- Suspend the Flying frame according to the chosen type of suspension

as described in section 3.3 on page 15.

- Release the two Locking pins at the front of the frame.

2. Prepare the first T10 cabinet

- Prepare the Front and Splay links of the first T10 cabinet as

described in section 2.4 on page 11.

3. Attach the Flying frame to the first T10 cabinet

- Lower the frame onto the cabinet until the Front links fit into the slots

at the front of the frame.

- Insert and lock the frame's Locking pins through the Front links of the

T10 cabinet on both sides.

- Release the upper Locking pin at the support point for the Splay link

on the center bar of the frame.

- Fold up the Splay link of the cabinet into the track of the frame's

center bar until the link hooks over the Locking pin.
To achieve this you may first have to lower the frame slightly more.

- Lift the frame by hand until the Splay link hooks into the Locking pin

and keep holding the frame in this position.

- Insert the second Locking pin (safety pin) to secure the Splay link.

- Lift the frame to a suitable working height to add the next cabinet.

T-Series Rigging manual

(1.1 EN)

Page 20 of 44

Advertising