Input patching (input configuration), Available input patchings, Selecting patchings – KLING & FREITAG K&F CD Remote User Manual

Page 28: 1 available input patchings, 2 selecting patchings

Advertising
background image

User's manual

K&F CD 44 Remote

KLING & FREITAG GMBH © 2014

Version 5.5

Page 28 of 50

12. Input Patching (Input Configuration)

CD 44 only!
With the input patching, you can configure the physical inputs. This way, you can, for
example, correct physically flipped inputs in the controller without having to change the
actual connectors, you can select if you want to connect a digital or analogue signal to the
inputs or you can create a mono-sum of the inputs 1 and 2.

12.1

Available input patchings

By default, the following patchings are available.

Input Patching

Function

Analog.default

Standard, analog

Analog.Flipped

1 and 2, or 3 and 4 flipped, analog

Analog.1+2 Mixed

Mono-sum of 1 and 2, analog

Digital.default

Standard, digital

Digital.Flipped

1 and 2, or 3 and 4 flipped, digital

Digital.1+2 Mixed

Mono-sum of 1 and 2, digital

You will find a detailed description of the individual patchings in the hardware manual.

12.2

Selecting Patchings

You can select the patchings available in the controller as follows:

1.

In the device window, click the current patching (Modes: Input:).

2.

Select the desired patching.

Advertising