4 event configuration – Signamax Managed Hardened PoE Industrial DIN-rail Mount Switch User Manual

Page 78

Advertising
background image

14 RMON

73

value is less than or equal to this threshold, and the last sample value was greater

than this threshold, a single event will be generated. A single event will also be

generated if the first sample, after this entry becomes valid, is less than or equal to

this threshold and the associated StartupAlarm is equal to fallingAlarm (2) or

risingOrFallingAlarm (3). After a falling event is generated, another such event will

not be generated until the sampled value rises above this threshold and reaches the

Rising Threshold.

Falling Event Index: The index of the eventEntry is used when a falling threshold is

crossed. The eventEntry identified by a particular value of this index is the same as

identified by the same value of the event Index object.

Step 6 Select Startup Alarm: rising alarm, falling alarm and rising or falling alarm.

Startup Alarm: The alarm that is sent when this entry is set to be valid for the first

time. If the first sample, after this entry becomes valid, is greater than or equal to the

Rising Threshold and alarm Startup Alarm is equal to rising Alarm (1) or rising Or

Falling Alarm (3), then a single rising alarm will be generated. If the first sample,

after this entry becomes valid, is less than or equal to the Falling Threshold and alarm

Startup Alarm is equal to fallingAlarm (2) or risingOrFallingAlarm (3), then a single

falling alarm will be generated.

Step 7 Set the Sample Interval over which the data is sampled and compared with the rising

and falling thresholds (in seconds).

Step 8 Configure the Owner that configures this entry and is therefore using the resources

assigned to it.

Step 9 Click <Create>, the lower part of the interface will show the RMON Alarm Entries.

14.4 Event Configuration