Non-field-replaceable units, 1 overview, 2 backplane – Artesyn Centellis 2000 Shelf - DC Installation and Use (June 2014) User Manual

Page 113: 1 overview 5.2 backplane, Chapter 5

Advertising
background image

Chapter 5

Centellis 2000 Shelf - DC Installation and Use (6806800G45F)

113

Non-Field-Replaceable Units

5.1

Overview

Within the Centellis 2000 Shelf - DC, there are fixed internal components:

Backplane

Alarm panel

Power Inlet

These components are passive and are non-field-replaceable units.

5.2

Backplane

The backplane is fully compliant with the PICMG 3.0 R3.0 Specification and it has been designed
with the following features:

Two node slots

Fabric interface channel 1 with direct connection between the two node slots.
The fabric interface channel 2 of node slot 1 is connected to user slot1.
The fabric interface channel 2 of slot 2 is connected to user slot 2.

Base interface with dual star interconnect

Update interface between the node slots

Base interface to the shelf manager slots

Bused IPMB-0 connections

Synchronization clock buses

The following interfaces are located within the zone 2:

Base interface

Fabric interface

Update channel interface

Synchronization clock interface

Advertising