12 updating the bios, 13 bios messages, 12 updating the bios 6.13 bios messages – Artesyn PrAMC-7311 Installation and Use (June 2014) User Manual

Page 113: Table 6-33, Example bios messages, Basic input output system

Advertising
background image

Basic Input Output System

PrAMC-7311 Installation and Use (6806800P34D)

113

6.12 Updating the BIOS

For information on updating the BIOS on your PrAMC-7311, please refer to the Basic Blade
Services Software for your release, listed in

Appendix B, Related Documentation

.

6.13 BIOS Messages

The following messages may be displayed, if for example, the system fails after making
changes in the setup menus.

If it is not possible to fix a problem with the help of this section, contact your local sales
representative or services for further support.

Save the changes

Save the Changes done

Table 6-32 Exit Menu

Section

Description

Table 6-33 Example BIOS Messages

Message

Explanation

Corrective Action

Allocation Error for

Resource conflict for the specified device

Run ISA or EISA configuration
utility to resolve conflict.

nnnn Cache SRAM Passed

nnnn represents the amount of system
cache in KBs successfully tested

None

CPU ID

CPU socket number for multi-processor
error

None

Diskette drive A error
Diskette drive B error

Drive A: or B: fails the BIOS POST disk
tests. Drive is selected via setup but is
either not present or is defective

Check the following:
The drive is defined with
proper disk type in setup
The disk drive is attached
correctly
The controller is enabled.

DMA Test Failed

ServerBIOS2 test error: Cannot write to
extended DMA

None

Entering SETUP...

Starting setup program

None