Hardware Preparation and Installation

PrAMC-7311 Installation and Use (6806800P34D)

38

4. Ensure that AMC module handle is in the extracted position: pulled outward, away

from the face plate.

5. Using your thumb, apply equal and steady pressure on the face plate as necessary

to carefully slide the AMC module into the guides rails.

6. Continue to gently push the module along the guide rails till the module is fully

engaged with the connector. Avoid using excessive force during this operation.

7. Wait for the blue LED to glow. The blue LED glows when the AMC module is

completely engaged with the connector.

8. Press module handle inwards toward the face plate to lock the AMC module on

AMC bay.

9. Wait for the blue LED to perform a series of long blinks. The blue LED blinks when

the handle is locked in position indicating module detection and activation by the
carrier board.

10.Observe blue LED status/activity. The module is fully installed when the blue LED

stops blinking and stays OFF.

Removal Procedure

The following describes how to remove an AMC module from the base board. The procedure
assumes that the base board is powered. If it is not powered, the steps regarding the blue LED
can be ignored and skipped.

1. Make sure you are in an ESD safe environment.

2. Remove any cables that are connected to the AMC module face plate connectors.

3. Gently pull the module latch outward, approximately 3 mm from its locked

position.

Advertising