4 timing specifications, Timing specifications, Table 33: mii timing characteristics – BECKHOFF ET1200 User Manual

Page 37: Figure 5: mii timing rx signals

Advertising
background image

MII Interface

Slave Controller

– ET1200 Hardware Description

III-27

4.4

Timing specifications

Table 33: MII timing characteristics

Parameter

Min

Typ

Max

Comment

t

RX_CLK

40 ns ± 100 ppm

RX_CLK period (100 ppm with maximum FIFO
Size only)

t

RX_setup

6

RX_DV/RX_DATA/RX_D[3:0] valid before rising
edge of RX_CLK

t

RX_hold

5

RX_DV/RX_DATA/RX_D[3:0] valid after rising
edge of RX_CLK

t

Clk

~ 1.44 µs

MI_CLK period (f

Clk

≈ 700 kHz)

t

Write

~ 92.16 µs

MI Write access time

t

Read

~ 91.44 us

MI Read access time

NOTE: For MI timing diagrams refer to Section I.

RX_DV

RX_D[3:0]

RX_ERR

RX_CLK

t

RX_setup

t

RX_hold

RX signals valid

t

RX_CLK

Figure 5: MII timing RX signals

Advertising