10 electrical specifications and timings, 1 absolute maximum ratings, 2 electrical characteristics – BECKHOFF ET1200 User Manual

Page 59: Electrical specifications and timings, Absolute maximum ratings, Electrical characteristics, Table 48: absolute maximum ratings, Table 49: operating conditions

Advertising
background image

Electrical Specifications and Timings

Slave Controller

– ET1200 Hardware Description

III-49

10 Electrical Specifications and Timings

10.1 Absolute Maximum Ratings

Table 48: Absolute Maximum Ratings

Symbol

Parameter

Condition

Min

Max

Units

V

CC

-V

SS

Supply voltage for
internal LDO

-0.3

5.5

V

I

CC

Supply current

Internal LDOs used for V

CC I/O

and

V

CC Core

110

mA

I

CC I/O

Supply current

V

CC I/O

sourced externally, LDO

used for V

CC Core

60

mA

I

CC Core

Supply current

V

CC I/O

and V

CC Core

sourced

externally

100

mA

V

ESC

ESD protection

Human body model, according to
MIL-STD-883E-3015.7 Class 1

2

kV

I

DC_ESD

Permanent current into
ESD protection diodes

Only in case of forward biased
ESD diodes. Input voltage above
V

CCI/O

or below V

SS

2

mA

NOTE: Supply current does not include output driver current for PDIs and LEDs.

10.2 Electrical Characteristics

Table 49: Operating Conditions

Symbol

Parameter

Min

Typ

Max

Units

V

CC

Power supply

3.0

5.0

5.5

V

V

CC I/O

I/O power supply

3.0

3.3

5.5

V

V

CC Core

Logic power supply

2.25

2.5

2.75

V

V

CC PLL

PLL power supply

2.25

2.5

2.75

V

V

CC I/O Ext

External I/O power supply

3.3

3.3

5.5

V

V

CC Core Ext

External logic power supply

2.5

2.5

2.75

V

V

CC PLL Ext

External PLL power supply

2.5

2.5

2.75

V

A

Ambient temperature

-40

85

°C