Table 52: ac characteristics – BECKHOFF ET1200 User Manual

Page 62

Advertising
background image

Electrical Specifications and Timings

III-52

Slave Controller

– ET1200 Hardware Description

Table 52: AC Characteristics

Symbol

Parameter

Min

Typ

Max

Units

f

CLK25

Clock source (OSC_IN) with initial accuracy

25 MHz ± 25 ppm

t

CLK25OUT

CLK25OUT rising edge after OSC_IN rising
edge

22

ns

t

TX_delay

TX_ENA/TX_D[3:0] edge (TX-Shift = 00) after
rising edge of
a) OSC_IN
b) CLK25OUT



a) 4
b) 22

ns

t

CPU_CLK

CPU_CLK (25 MHz) rising edge after OSC_IN
rising edge

4

t

POR_Sample

POR value sample time after power good

84

ms

t

Driver_Enable

Output drivers enabled after POR values
sampled (not PDI and not Sync/LatchSignals)

80

ns

t

Reset_In

External reset input time

50

ns

t

Reset_Out

ET1200 Reset output time

80

84

ms

t

Reset_Func

ET1200 functional after RESET signal high
(EEPROM not loaded, PDI not functional)

50

µs

t

Startup

Startup time (PDI operational after power
good, without SII loading error)

340

ms

The AC characteristics of the PDIs, Distributed Clocks, SII EEPROM I

2

C interface, and MII interface

can be found in their respective chapters.