Table 53: forwarding delays – BECKHOFF ET1200 User Manual

Page 64

Advertising
background image

Electrical Specifications and Timings

III-54

Slave Controller

– ET1200 Hardware Description

Table 53: Forwarding Delays

Symbol

Parameter

Min

Average

Max

Units

t

Diff

Average difference processing delay minus
forwarding delay (without RX FIFO jitter)
between any two ports

20

ns

t

EE

EBUS port to EBUS port delay (FIFO size 7):
a) Through ECAT Processing Unit
(processing), Low Jitter off
b) Alongside ECAT Processing Unit
(forwarding), Low Jitter off
c) Through ECAT Processing Unit
(processing), Low Jitter on
d) Alongside ECAT Processing Unit
(forwarding), Low Jitter on

a) 140
b) 120
c) 150
d) 130

a) 150
b) 130
c) 155
d) 135

a) 160
b) 140
c) 160
d) 140

ns

t

EM

EBUS port to MII port delay (FIFO size 7):
a) Through ECAT Processing Unit
(processing)
b) Alongside ECAT Processing Unit
(forwarding)

a) 145
b) 125

a) 170
b) 150

a) 195
b) 175

ns

t

ME

MII port to EBUS port delay (FIFO size 7):
a) Through ECAT Processing Unit
(processing), Low Jitter off
b) Alongside ECAT Processing Unit
(forwarding), Low Jitter off
c) Through ECAT Processing Unit
(processing), Low Jitter on
d) Alongside ECAT Processing Unit
(forwarding), Low Jitter on

a) 255
b) 235
c) 265
d) 245

a) 280
b) 260
c) 290
d) 270

a) 305
b) 285
c) 315
d) 295

ns

t

MM

MII port to MII port delay
(FIFO size 7, TX Shift=00):
Through ECAT Processing Unit (processing)

280

305

335

ns

NOTE: Average timings are used for DC calculations.